EFSVALVES / APPLICATION ENGINEERING

Flare Header, Gas Recovery & Emergency Bypass

One possible conceptual arrangement showing recoverable flow routed to an FGR system, an independent primary flare route, and an optional project-specific EF-SHP high-capacity bypass.
Swipe horizontally to inspect the complete schematic.
Flare header, gas recovery and optional emergency shear pin bypass arrangement Relief and vent sources feed a flare header and knockout drum. Recoverable flow is routed to a gas recovery system. The primary flare route remains available. A separate optional branch contains an EF-SHP shear pin device for a project-specific high-capacity emergency bypass. RELIEF / VENT SOURCESFLARE COLLECTION & LIQUID SEPARATIONRECOVERY / SAFE DISPOSAL ProcessUnit ARelief / vent source ProcessUnit BRelief / vent source FlareHeader KnockoutDrumConceptual locationSeparated liquid Flare Gas RecoverySystemWithin available recovery capacity Flare SystemPrimary safe-disposal routeRemains available by design TO FGRPURGE / SWEEP · WHERE APPLICABLE WITHIN CAPACITY EMERGENCY FLOW TO FLARE PRIMARY FLARE ROUTE · AVAILABLE CLOSED · 0°OPEN · 90° Optional EF-SHP emergency bypassProject-specific, non-reclosing high-capacity relief branchNot presented as the sole flare route P₁UPSTREAM PᵦBACKPRESSURE Simplified concept only. Isolation, seals, controls, safeguards, instrumentation and redundancy are not fully represented.
Normal operation: Recoverable process gas is routed to the FGR system. Where required, purge or sweep gas can continue toward the flare while the optional EF-SHP bypass remains closed.
Recovery routePurge / sweepEmergency route